Part Number Hot Search : 
4051B EE07964 7625P ON0414 1N4946 VTD210L A08TB60 H162102B
Product Description
Full Text Search
 

To Download PTF14A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 new product electronic thermostat e5l ideal for simple built-in control. ? a high switching capacity of 10 a at 250 vac enables direct load switching.  a sensor is provided to enable immediate application.  sockets with finger protection (PTF14A-e) or without finger protection (PTF14A) can be used.  simple operation and settings. even simpler with digital models. model number structure model number legend ordering information electronic thermostats e5l-a @ e5l-c @ note: the e5l-c is not available with a set temperature range of 0 to 50 c. options (order separately) sockets 1 2 e5l- @@ 1. setting and indication methods a: analog setting, no display c: digital setting, display 2. set temperature ? 30-20 : ? 30 to +20 c 0-50 : 0 to +50 c 0-100 : 0 to +100 c 100-200 : +100 to +200 c size type control method control output model 45 35 mm plug-in on/off operation relay e5l-a -30-20 e5l-a 0-50 e5l-a 0-100 e5l-a 100-200 size type control method control output model 45 35 mm plug-in on/off operation relay e5l-c -30-20 e5l-c 0-100 e5l-c 100-200 type model front-connecting socket PTF14A PTF14A-e
e5l 2 ratings and ch aracteristics ratings note: do not use the output from an inverter as the power supply. characteristics * the accuracy of the accessory thermistor is not included. item model e5l-a @ e5l-c @ power supply voltage 100 to 240 vac, 50/60 hz operating voltage range 85% to 110% of the rated supply voltage power consumption approx. 3 va inputs element-interchangeable thermistor control method on/off control control output spdt contacts, 250 vac, 10 a, cos = 1 (resistive load) spst-no contacts, 250 vac, 10 a, cos = 1 (resistive load) setting method analog setting digital setti ngs using keys on front panel indication method no display lcd digital disp lay (character height: 12 mm) other functions ? setting protection (key protection) ? input shift ? direct/reverse operation ambient temperature ? 10 to 55 c (with no icing or condensation) ambient humidity 25% to 85% storage temperature ? 25 c to 65 c (with no icing or condensation) item model e5l-a @ e5l-c @ indication accuracy --- (1 c + 1 digit) max. * setting accuracy --- (1 c + 1 digit) max. * hysteresis ? 30 to 20 c models: approx. 0.5 to 2.5 c (variable) 0 to 50 c models: approx. 0.5 to 4 c (variable) 0 to 100 c models: approx. 0.5 to 4 c (variable) 100 to 200 c models: approx. 0.7 to 4 c (variable) 1 to 9 c (in increments of 1 c) repeat accuracy 1% fs max. --- minimum scale (standard scale) ? 30 to 20 c models and 0 to 50 c models: 5 c 0 to 100 c models and 100 to 200 c models: 10 c --- influence of temperature --- ((1% of pv or 2 c, whichever is great er) +1 digit) max. influence of voltage --- sampling period --- 2 s insulation resistance 100 m ? max. (at 500 vdc) dielectric strength 2,300 vac, 50/60 hz for 1 min (between charged termi nals and uncharged metallic parts, between power supply terminals and input terminals, between power supply term inals and output terminals, and between input terminals and output terminals) vibration (malfunction) frequency of 10 to 55 hz, 0.5-mm double amplitude for 10 min each in x, y, and z directions vibration (destruction) frequency of 10 to 55-hz, 0.75-mm double amplitud e for 2 h each in x, y, and z directions shock (malfunction) 147 m/s 2 , 3 times each in 6 directions 100 m/s 2 , 3 times each in 6 directions shock (destruction) 294 m/s 2 , 3 times each in 6 directions electrical life expectancy (control output relay) 100,000 operations min (a t maximum applicable load) memory protection --- non-volatile memory (100,000 write operations) weight (thermostat) approx. 80 g (thermostat only) degree of protection front panel: ip40, terminals: ip00 approved standards --- conformed standards en 61010-1 (iec 61010-1), pollution degree 2, overvoltage category ii emc directives emi: en61326-1 radiated emi: en55011 group1 classa conducted emi: en55011 group1 classa ems: en61326-1 electrostatic dischar ge immunity: en61000-4-2 electromagnetic field str ength immunity: en61000-4-3 burst noise immunity: en61000-4-4 conducted disturbance immunity: en61000-4-6 surge immunity: en61000-4-5 voltage dip and power interruption immunity: en6100-4-11
e5l 3 external connections note: for thermistor wiring, separate the input po wer supply and load lines as much as possibl e to avoid the influence of inductive n oise. nomenclature dimensions (unit: mm) thermostats e5l-a @ e5l-c @ * control output heating load: terminals 8 and 12 cooling load: terminals 4 and 12 be careful of the cooling load contac ts, because they will be electrically charged even when the e5l inpu t power supply is off. * control outputs: terminals 8 and 12 use the keys on the front panel to set direct/reverse operation. 250 vac, 10 a control output * input power supply: 100 to 240 vac element- interchangeable thermistor 250 vac, 10 a control output * input power supply: 100 to 240 vac element- interchangeable thermistor hysteresis adjuster (diff.) operation indicator temperature dial operation indicator operation indicator output status heating load cooling load lit red. on off not lit. off on e5l-a @ mode key down key up key operation indicator set value indicator protection indicator process value and set value display operation indicator: on set value indicator: sv lit when the set value is displayed. setting protecti on indicator: lit when setting protection is set. operation indicator output status reverse operation direct operation lit on on not lit off off e5l-c @ 6.4 64 75.0 (4.6) 45 35 e5l-a @ 6.4 64 70.4 45 35 e5l-c @
e5l 4 wiring connection sockets (order separately) accessories e52-the-e5l element-inter changeable thermistor temperature sensors (order separately) e52-the5a, e52-the6d, and e52-the6f temperature sensor s can be ordered separately. for details, refer to an omron web site . dimensions terminal arrangement and internal connections mounting hole dimensions included with the following models: ? 30 to 20 c, 0 to 50 c, and 0 to 100 c. temperature range note: pvc cable is heat resistant from ? 40 to 105 c. ptfe cable is heat resistant from ? 40 to 250 c. * use a 0 to 100 c thermistor for 0 to 50 c applications. tolerance included with 100 to 200 c models. mounting brackets (two) 30 max. 45.5 max. 78.5 max. two, 4.5 x 6 mounting holes 8 35.4 3.4 7 0.2 14, m3.5 x 8 sems screws 7 0.2 33 max. 45.5 max. 78.5 max. two, 4.5 x 6 mounting holes 14, m3.5 x 8 sems screws 8 35.5 3.4 PTF14A PTF14A-e socket wi th finger protection 8 11 10 9 12 13 14 7 6 5 4 3 2 1 (top view) 68 0.3 36 0.2 two, m4 or 4.5-dia. holes (top view) note: can be mounted to a din track. color code pvc cable (12/0.18) (5.5-dia.) 10 30 500 30 temperature range color code nominal resistance thermistor constant lead wires ? 30 to 20 cblue6 k ? (0 c) 3,390 k heat-resistant pvc cable 0 to 100 c * black 6 k ? (0 c) 3,390 k 100 to 200 c yellow 0.55 k ? (200 c) 4,300 k ptfe measured temperature tolerance ? 30 to 100 c 2 c max. 100 to 200 c measured temperature 2% max. color code 10 15 60 500 30 5-dia. max. ptfe cable (7/0.2)
e5l 5 operating the e5l-c @ set temperature 1. press the key to enter the set temperature mode. 2. press the and keys to set the temperature. the display will continue to change for as long as the key is held down. note: the default setting is the lowest temperature in the range. setting the hysteresis 1. press the key to enter the hysteresis mode. 2. press the and keys to set the value. each time the key is pressed, the setting will change by 1 c. the setting will not continue to change even if the key is held down. the key must be released after each change. the hyst eresis can be set from 1 to 9 c, in increments of 1 c. note: the default setting is 1 c. setting the temperature input shift 1. press the key for at least 3 s to enter the temperature input shift mode. 2. press the and keys to set the value. each time the key is pressed, the setting will change by 1 c. the setting will not continue to change as the key is held down. the key must be released after each change. the input shift can be set from ? 9 to 9 c, in increments of 1 c. note: 1. the default setting is 0 c. 2. the control output turns off while this setting is being made. setting direct or reverse operation 1. press the key for at least 3 s to enter the direct/reverse selection mode. 2. press the and keys to set the value. direct operation can be set by pressing the key, and reverse operation can be set by pressing the key. note: 1. the default setting is for reverse operation. 2. the control output turns off while this setting is being made. process value power on set temperature display process value display setting protection press the key for at least 3 s. press the key for less than 1 s. temperature input shift direct/reverse operation set temperature hysteresis control stops. press the and keys for at least 1 s. press the and keys for at least 1 s. press the and keys for at least 1 s. press the key for at least 3 s. press the key for at least 3 s. press the key for less than 1 s. press the key for less than 1 s. hysteresis display +1 c +5 c +9 c off power on set temperature example: -5c ? 4c off power on hysteresis (1c set) example: 64c set temperature: 65c control output (relay) control output (relay) hysteresis (1c set) reverse operation (heating control) direct operation (cooling control) input shift display thermistor measured temperature tempera- ture dis- play (no shift) 25 c25 c (+9 c shift) 25 c34 c (-9 c shift) 25 c16 c direct/reverse operation display reverse operation direct operation
e5l 6 setting protection 1. setting protection (process value display) press the and keys simultaneously while the process value is being displayed to chan ge to the setting protection state. 2. setting protection (set temperature display) from the setting protection (process value display) mode, press the and keys simultaneously to change to the setting protection (set temper ature display) state. 3. from the setting protection (set te mperature display) mode, press the and keys simultaneously to return to the process value display with no setting protection. note: 1. setting protection disables ke y operations to prevent the settings from being changed ac cidentally. will be lit while protection is in effect. 2. protection will be maintained even when the power supply is turned off and on. error displays and causes e5l-a @ when a thermistor disconnection occurs, the built-in relay operates at the off side (when no contacts are used). e5l-c @ when an error occurs, the display shows the error code. take the necessary measures, referring to the following table. note: 1. errors are not displayed while settings are being changed, except for memory errors. the c ontrol output status will be as shown in the above table while the set temperature or h ysteresis is being set. the control output will be off while the temperature input sh ift or direct/ reverse operation setting is being set. key operations will be possible when an erro r occurs, except for a memory error. 2. the setting protection indicator ( ) and set value indicator ("sv") will be continued ev en when settings are protected, except w hen a memory error occurs. display example display process value display set temperature display thermistor no contacts (terminal numbers 8 and 12) * heating load nc contacts (terminal numbers 4 and 12) * cooling load disconnection off on short-circuit off on display meaning cause control output fff (lit) overflow the process value is higher than the set temperature range. reverse operation: off direct operation: on --- (lit) underflow the process value is lower than the set temperature range reverse operation: on direct operation: off fff (flashing) thermistor short- circuited the thermistor is short-circuited. reverse operation: off direct operation: off --- (flashing) thermistor disconnected the thermistor is disconnected. reverse operation: off direct operation: off e11 (lit) memory error the thermostat has failed. off
e5l 7 safety precautions do not touch the terminals wh ile power is being supplied. doing so may occasionally result in minor injury due to electric shock. do not allow pieces of metal, wire clippings, or fine metallic shavings or filing s from installation to enter the product. doing so may occasionally result in electric shock, fire, or malfunction. do not use the product where subject to flammable or explosive gas. otherwise, minor injury from explosion may occasionally occur. never disassemble, modify, or repair the product or touch any of the internal parts. mino r electric shock, fire, or malfunction may occasionally occur. if the output relays are used past their life expectancy, contact fusing or burning may occasionally occur. always consider the application c onditions and use the output relays within their rated load and electrical life expectancy. the life expectancy of output relays varies considerably with the output load and switching conditions. tighten the terminal screws to between 0.74 and 0.90 nm. loose screws may occasional ly result in fire. set the parameters and wiring of the product so that they are suitable for the system being controlled. unexpected operation may occasionally result in property damage or accidents. a malfunction in the product may occasionally make control operations impossible or prevent alarm outputs, resulting in property damage. to maintain safety in the event of malfunction of the product, take appropriate safety measures, such as installi ng a monitoring device on a separate line. be sure to observe the following precautions to prevent failure to operate, malfunction, or adverse effects on the performance and functions of the thermostat. not doing so may occasionally result in unexpected events. 1. the product is designed for indoor use only. do not use the product outdoors or in any of the following locations. ? locations directly subject to heat radiated from heating equipment ? locations subject to water or oil ? locations subject to direct sunlight ? locations subject to dust or corr osive gas (in particular, sulfide gas and ammonia gas) ? locations subject to sudden or extreme temperature changes ? locations subject to icing or condensation ? locations subject to vibration or shock 2. use and store the product within the rated temperature and humidity ranges. provide fo rced cooling if required. 3. to allow heat to escape, do not block the area around the product. 4. be sure to wire the product pr operly with the co rrect terminal polarity. 5. use the specified size of crimped terminals for wiring (m3.5, width of 6.8 mm or less). to connect bar e wires to the terminals, use copper wires with a gauge of aw g24 to awg14 (equal to a cross-sectional area of 0.205 to 2.081 mm 2 ). (the stripping length is 5 to 6 mm.) do not connect more than two wires or two crimp terminals to one terminal. when c onnecting two wires, they must be of the same size and type. 6. do not connect anything to terminals that are not used. 7. allow as much space as possi ble between the thermostat and devices that generate powerful high frequencies or surges. separate the wiring to the thermo stat from high-voltage or high- current lines, and do not place the wiring to the thermostat in parallel with or in the same wiring paths as power lines. 8. use this product within the rated load and power supply specifications. 9. turn on the power supply at le ast 30 minutes prior to starting control operations. 10. a switch or circuit breaker must be provided close to the thermostat. the switch or circuit breaker must be within easy reach of the operator, and mu st be marked as a disconnecting means for the thermostat. 11. do not use paint thinner or similar solvents to clean the thermostat. use standard grade alcohol. 12. design the system (e.g., the control panel) considering the 2.5 second of delay between turning on the thermostat and stabilization of the thermostat's output. caution precautions for safe use
e5l 8 mounting the thermostat 1. using the PTF14A socket or pt f14a-e socket with finger protection, mount the thermostat to the bracket that is provided. 2. the structure does not allow the case to be removed. do not apply excessive force when mounting the thermostat. settings 1. e5l-a @ temperature dial ? the temperature dial has some backlash. to adjust the temperature more accurately, turn the dial clockwise when adjusting the temperature. ? do not change the setting of the temperature dial more than 20 times. ? do not attempt to turn the dial past the range of the setting scale. applying excessive force may damage the thermostat. 2. e5l-a @ hysteresis dial ? this dial can be used to set hyst eresis for the on/off operation. turn the dial clockwise to reduce the hysteresis and counterclockwise to increase the hysteresis. increase the hysteresis to extend the life of the relay by preventing relay chattering caused by the cont rol output turning on and off frequently. ? do not change the setting of the temperature dial more than 20 times. mounting the thermistor ? select a location for the temperature sensor of the thermistor where the temperature distribution of sensing objects will not be changed by installation. ? insert the temperature sens or as far in as possible. ? when measuring fluid temperature, the thermistor should be installed against the current. before mounting, take factors such as the bending moment of inertia and vibration into consideration. ? do not apply mechanical force to the temperature-sensing part of the thermistor. ? the e52-the @@ thermistor can be used for applications that require metal protective tubing. consult with your omron representative. other precautions ? do not use the e5l-c @ if the front sheet is peeling or torn. ? use appropriate tools to disassembl e the thermostat for disposal. precautions for correct use (98.6) (4.6) (4.6) (98.6) e5l+PTF14A e5l+PTF14A-e
9 memo
memo 10
warranty and application considerations read and understand this catalog please read and understand this catalog before purchasing the products. please consult your omron representative if you have any questions or comments. warranty and limitations of liability warranty omron's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by omron. omron makes no warranty or representation, expr ess or implied, regarding non-infringement, merchantability, or fitness for particular purpose of the products. any buyer or user acknowledges that the buyer or user alone has determined that the products will suitably meet the requirements of their intended use. omron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indirect , or consequential damages, loss of profits, or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, neglige nce, or strict liability. in no event shall the resp onsibility of omron for any act e xceed the individual pr ice of the product on which liability is asse rted. in no event shall omron be responsible for warra nty, repair, or other claims regarding the products unless omron's analysis confirms that the products were properly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. application considerations suitability for use omron shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. take all necessary steps to determine th e suitability of the product for the systems, machines, and equipment with which it wil l be used. know and observe all prohibitions of use applicable to this product. never use the products for an application involv ing serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron products are properly rated and installed for th e intended use within the overall equipment or system. disclaimers performance data performance data given in this catalog is provided as a guide fo r the user in determining suitability and does not constitute a warranty. it may represent the result of omron's test conditions, and the users mu st correlate it to actual application requirements. actual performance is subject to the omron warranty and limitations of liability. change in specifications product specifications and accessories may be changed at any time based on improvements and other reasons. consult with your omron representative at any time to conf irm actual specifications of purchased product. dimensions and weights dimensions and weights are nominal and are not to be used fo r manufacturing purposes, even when tolerances are shown.
authorized distributor: in the interest of product improvement, specifications are subject to change without notice. cat. no. h162-e1-01 omron industrial automation global: www.ia.omron.com printed in japan 0309 (0309) omron corporation industrial automation company regional headquarters omron europe b.v. wegalaan 67-69-2132 jd hoofddorp the netherlands tel: (31)2356-81-300/fax: (31)2356-81-388 omron electronics llc one commerce drive schaumburg, il 60173-5302 u.s.a. tel: (1) 847-843-7900/fax: (1) 847-843-7787 omron asia pacific pte. ltd. no. 438a alexandra road # 05-05/08 (lobby 2), alexandra technopark, singapore 119967 tel: (65) 6835-3011/fax: (65) 6835-2711 omron (china) co., ltd. room 2211, bank of china tower, 200 yin cheng zhong road, pudong new area, shanghai, 200120, china tel: (86) 21-5037-2222/fax: (86) 21-5037-2200 control devices division h.q. analog controller division shiokoji horikawa, shimogyo-ku, kyoto, 600-8530 japan tel: (81) 75-344-7080/fax: (81) 75-344-7149 2-2-1 nishikusatsu, kusatsu-shi, shiga, 525-0035 japan tel: (81) 77-565-5216/fax: (81) 77-565-5568 ? omron corporation 2009 all rights reserved.


▲Up To Search▲   

 
Price & Availability of PTF14A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X